ECOLAB INC., INSTITUTIONAL PRODUCTS DIVISION -- OASIS 297 -- 7930-01-380-8467
===================== Product Identification =====================
Product ID:OASIS 297
MSDS Date:09/25/1995
FSC:7930
NIIN:01-380-8467
=== Responsible Party ===
Company Name:ECOLAB INC., INSTITUTIONAL PRODUCTS DIVISION
Address:370 WABASHA STREET
City:ST. PAUL
State:MN
ZIP:55102-1307
Country:US
Info Phone Num:612-293-2233
Emergency Phone Num:612-293-2233
CAGE:DO852
=== Contractor Identification ===
Company Name:ECOLAB INC., INSTITUTIONAL PRODUCTS DIVISION
Address:370 WABASHA STREET
City:ST. PAUL
State:MN
ZIP:55102-1307
Country:US
Phone:612-293-2233
CAGE:DO852
Company Name:ECOLAB PROFESSIONAL PRODUCTS DIVISION OF ECOLAB INC.
Address:ECOLAB CENTER
Box:City:ST PAUL
State:MN
ZIP:55102
Country:US
Phone:800-352-5326
CAGE:85884
============= Composition/Information on Ingredients =============
Ingred Name:PHOSPHORIC ACID (SARA 313) (CERCLA)
CAS:7664-38-2
RTECS #:TB6300000
Fraction by Wt: 15.0%
Other REC Limits:1 MG/M3 STEL 3 MG/M3
OSHA PEL:1 MG/M3
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ingred Name:THIS PRODUCT CONTAINS NO OTHER COMPONENTS CONSIDERED
HAZARDOUS ACCORDING TO THE CRITERIA OF 29 CFR 1910.1200.
Fraction by Wt: NA
Other REC Limits:NONE RECOMMENDED
OSHA PEL:NOT RELEVANT
ACGIH TLV:NOT RELEVANT
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EFFECTS OF OVEREXPOSURE TO
CONCENTRATE: SKIN/EYES: CAN CAUSE SEVERE IRRITATION. POSSIBLE
CHEMICAL BURNS. INGESTION: HARMFUL. CAN CAUSE CHEMICAL BURNS TO
MOUTH, THROAT, STOMACH. IF INHALED VAPORS CAUSE IRRITATION
INCLUDING BURNING TASTE, SNEEZING, COUGHING, DIFFICULTY BREATHING.
Effects of Overexposure:NK *INHALATION: IMMEDIATELY REMOVE TO FRESH
AIR. IMMEDIATELY CALL A POISON CONTROL CENTER OR DR OR ECOLAB 24
HOUR MEDICAL EMERGENCY NUMBER (1-800-328-0026).
Medical Cond Aggravated by Exposure:PEOPLE W/ASTHMA OR OTHER LUNG
PROBLEMS MAY BE MORE AFFECTED.
======================= First Aid Measures =======================
First Aid:EYES: IMMED FLUSH W/LOTS COOL RUNNING WATER. REMOVE CONTACTS,
CONTINUE FLUSHING >15 MIN HOLDING EYELIDS APART TO ENSURE RINSING
ENTIRE EYE. CALL DR. SKIN: IMMED FLUSH W/LOTS COOL RUNNING WATER
>15 MIN REMOVING CONTAM CLOTHES/SHOES. WASH CLOTHES BEFORE REUSE.
INGEST: RINSE MOUTH AT ONCE, THEN DRINK 1-2 LG GLASSES WATER/MILK.
DON'T INDUCE VOMITING. NEVER GIVE ANYTHING BY MOUTH TO UNCONSCIOUS
PERSON.
===================== Fire Fighting Measures =====================
Extinguishing Media:THIS PRODUCT DOES NOT SUPPORT COMBUSTION.
Unusual Fire/Explosion Hazard:NONE
================== Accidental Release Measures ==================
Spill Release Procedures:RINSE SMALL AMOUNTS TO DRAIN WHERE POSSIBLE.
DIKE OR DAM LARGE SPILLS. PUMP TO CONTAINERS OR SOAK UP ON INERT
ABSORBENT. FLUSH RESIDUE TO SANITARY SEWER. RINSE AREA THOROUGHLY.
====================== Handling and Storage ======================
Handling and Storage Precautions:USE SOLUTION PH = 2.0-3.0 @ 10%
============= Exposure Controls/Personal Protection =============
Respiratory Protection:CONCENTRATE: AVOID BREATHING MISTS OR VAPORS OF
THIS PRODUCT.
Protective Gloves:RUBBER. PROTECT CUFF/GAUNTLET PREFERRED.
Eye Protection:USE CHEMICAL SPLASH GOGGLES**
Other Protective Equipment:**FOR CONTINUED OR SEVERE EXPOSURE WEAR FACE
SHIELD OVER THE GOGGLES.
Supplemental Safety and Health
AVOID CONTACT W/USE SOLUTIONS. THESE MAY ALSO BE HAZARDOUS.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:212F,100C
Spec Gravity:1.119-1.123
pH:1-1.5
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR MAGENTA LIQUID, FRESH LEMON SCENT
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NK
Stability Condition to Avoid:DO NOT MIX W/ANYTHING BUT WATER. DO NOT
MIX W/CHLORINATED DETERGENTS OR SANITIZERS. WILL CAUSE HAZARDOUS
VAPORS.
==================== Disposal Considerations ====================
Waste Disposal Methods:CONSULT STATE & LOCAL AUTHORITIES FOR
RESTRICTIONS ON DISPOSAL OF CHEMICAL WASTE. UNUSED PRODUCT AS A
WASTE IS CORROSIVE (D002) BY RCRA CRITERIA.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.