ALLIED-SIGNAL INC, ENGINEERED MATERIALS SECTOR -- REFRIGERANT 500 -- 6830-01-357-7646
===================== Product Identification ===================== Product ID:REFRIGERANT 500 MSDS Date:01/09/1995 FSC:6830 NIIN:01-357-7646 === Responsible Party === Company Name:ALLIED-SIGNAL INC, ENGINEERED MATERIALS SECTOR Address:COLUMBIA RD AND PARK AVE Box:1087R City:MORRISTOWN State:NJ ZIP:07960 Country:US Info Phone Num:800-522-8001 Emergency Phone Num:800-522-8001 CAGE:1L164 === Contractor Identification === Company Name:ALLIED-SIGNAL INC Box:2332R City:MORRISTOWN State:NJ ZIP:07962-2332 Country:US Phone:201-455-4414 CAGE:1L164 Company Name:NEW ERA ENVIRONMENTAL Address:44880 FALCON PLACE SUITE 105 Box:City:STERLING State:VA ZIP:20166 Country:US Phone:703-904-7570 CAGE:0Z1V9 ============= Composition/Information on Ingredients ============= Ingred Name:DICHLORODIFLUOROMETHANE (SARA III) (FREON 12) CAS:75-71-8 RTECS #:PA8200000 Other REC Limits:NONE RECOMMENDED OSHA PEL:1000 PPM ACGIH TLV:1000 PPM; 9394 EPA Rpt Qty:5000 LBS DOT Rpt Qty:5000 LBS Ozone Depleting Chemical:1 Ingred Name:DIFLUOROETHANE (FC-152A) CAS:75-37-6 RTECS #:KI1410000 Other REC Limits:NONE RECOMMENDED ===================== Hazards Identification ===================== Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:INHALATION OF HIGH CONCENTRATIONS IS HARMFUL & MAY CAUSE HEART IRREGULARITIES, UNCONSCIOUSNESS, DEATH. INTENTIONAL MISUSE MAY CAUSE DEATH W/O WARNING. VAPORS REDUCE OXYGEN CONTENT OF THE AIR (ASPHYXIA TION). LIQUID CONTENT MAY CAUSE FROSTBITE. Explanation of Carcinogenicity:NONE OF THE INGREGREDIENTS PRESENT AT 0.1% OR GREATER ARE LISTED BY IARC, NTP, OSHA OR ACGIH AS CARCINOGENS. Effects of Overexposure:LIQUID CONTACT:FROSTBITE. INHALATION:HIGH CONCENTRATIONS; COUGH, DIFFICULTY BREATHING, SHORTNESS OF BREATH, IRREGULAR PULSE, PALPITATIONS, INADEQUATE CIRCULATION, ABNORMAL KIDNEY FUNCTION. Medical Cond Aggravated by Exposure:INDIVIDUALS W/PRE-EXISTING DISEASES OF CNS, CARDIOVASCULAR SYTEM, LUNGS OR KIDNEYS MAY HAVE INCREASED SUSCEPTIBILITY TO TOXICITY OF EXCESSIVE EXPOSURES. ======================= First Aid Measures ======================= First Aid:IF IRRITATION PERSISTS OR IS SEVERE, GET MEDICAL ATTENTION. EYE:FLUSH W/WATER FOR 15 MIN. SKIN:FLUSH AFFECTED AREA W/WATER. TREAT FOR FROSTBITE BY GENTLY WARMING AFFECTED AREA. INHALED: REMOVE FROM EX POSURE. KEEP VICTIM CALM. AID OR RESTORE BREATHING AS NEEDED. INGESTED:NOT CONSIDERED A POTENTIAL ROUTE OF EXPOSURE. ===================== Fire Fighting Measures ===================== Flash Point:WILL NOT BURN Extinguishing Media:AS APPROPRIATE FOR COMBUSTIBLES IN AREA. Fire Fighting Procedures:SELF-CONTAINED BREATHING APPARATUS IS REQUIRED IF CYLINDERS RUPTURE OR RELEASE UNDER FIRE CONDITIONS. USE WATER SPRAY/FOG TO COOL CONTAINERS. Unusual Fire/Explosion Hazard:CYLINDERS ARE EQUIPPED W/TEMP/PRESSURE RELIEF DEVICES BUT MAY STILL RUPTURE UNDER FIRE CONDITIONS. DECOMPOSITION MAY OCCUR. ================== Accidental Release Measures ================== Spill Release Procedures:VENTILATE AREA-ESPECIALLY LOW PLACE WHERE HEAVY VAPORS MIGHT COLLECT. WEAR SELF-CONTAINED BREATHING APPARATUS FOR LARGE SPILLS. REMOVE OPEN FLAMES. Neutralizing Agent:MFR GAVE NO INFORMATION ON MSDS. ====================== Handling and Storage ====================== Handling and Storage Precautions:AVOID BREATHING VAPORS. AVOID LIQUID CONTACT W/SKIN OR EYES.USE W/SUFFICIENT VENTILATION TO KEEP EMPLOYEE EXPOSURE BELOW RECOMMENDED LIMITS. Other Precautions:STORE IN CLEAN,DRY AREA. DO NOT HEAT ABOVE 125F. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:UNDER NORMAL MFG CONDITIONS NO RESPIRATORY PROTECTION IS REQUIRED WHEN USING THIS PRODUCT.SELF-CONTAINED BREATHING APPARATUS (SCBA) IS REQUIRED IF SPILL OCCURS. Ventilation:NORMAL VENTILATION FOR STDANDARD MFG PROCEDURES. IS GENERALLY ADEQUATE. USE LOCAL EXHAUST WHEN LARGE AMOUNTS RELEASED. Protective Gloves:IMPERVIOUS GLOVES Eye Protection:CHEMICAL SPLASH GOGGLES. Other Protective Equipment:SELF-CONTAINED BREATHING APPARATUS IS REQUIRED IF A SPILL OCCURS Work Hygienic Practices:MFR GAVE NO INFORMATION ON MSDS. Supplemental Safety and Health VENTILATION:MECHANICAL VENTILATION SHOULD BE USED IN LOW PLACES. ================== Physical/Chemical Properties ================== HCC:G3 NRC/State Lic Num:NONE Boiling Pt:B.P. Text:-27F,-33C Vapor Pres:232 PSI Vapor Density:3.7 Spec Gravity:1.16 G/CC Evaporation Rate & Reference:<1 (CARBON TET = 1) Appearance and Odor:LIQUIFIED GAS, COLORLESS, SLIGHT ETHEREAL ODOR, CLEAR APPEARANCE. Percent Volatiles by Volume:100 ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES INCOMPATIBLE WITH ALKALI OR ALKALINE EARTH METALS - POWDERED AL, ZN, BE, ETC. Stability Condition to Avoid:AVOID OPEN FLAMES AND HIGH TEMPERATURES. Hazardous Decomposition Products:DECOMPOSED BY HIGHTEMPERATURES (OPEN FLAME, GLOWING METAL SURFACES,ETC) FORMING HCL OR HF ACIDS, CARBONYL HALIDES. Conditions to Avoid Polymerization:WILL NOT OCCUR. ==================== Disposal Considerations ==================== Waste Disposal Methods:COMPLY WITH LOCAL, STATE & FEDERAL REGULATIONS. RECLAIM BY DISTILLATION OR REMOVE TO A PERMITTED WASTE DISPOSAL FACILITY. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.