ALLIED-SIGNAL INC, ENGINEERED MATERIALS SECTOR -- REFRIGERANT 500 -- 6830-01-357-7646
=====================  Product Identification  =====================

Product ID:REFRIGERANT 500
MSDS Date:01/09/1995
FSC:6830
NIIN:01-357-7646
=== Responsible Party ===
Company Name:ALLIED-SIGNAL INC, ENGINEERED MATERIALS SECTOR
Address:COLUMBIA RD AND PARK AVE
Box:1087R
City:MORRISTOWN
State:NJ
ZIP:07960
Country:US
Info Phone Num:800-522-8001
Emergency Phone Num:800-522-8001
CAGE:1L164
=== Contractor Identification ===
Company Name:ALLIED-SIGNAL INC
Box:2332R
City:MORRISTOWN
State:NJ
ZIP:07962-2332
Country:US
Phone:201-455-4414
CAGE:1L164
Company Name:NEW ERA ENVIRONMENTAL
Address:44880 FALCON PLACE SUITE 105
Box:City:STERLING
State:VA
ZIP:20166
Country:US
Phone:703-904-7570
CAGE:0Z1V9

=============  Composition/Information on Ingredients  =============

Ingred Name:DICHLORODIFLUOROMETHANE (SARA III) (FREON 12)
CAS:75-71-8
RTECS #:PA8200000
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM; 9394
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ozone Depleting Chemical:1

Ingred Name:DIFLUOROETHANE (FC-152A)
CAS:75-37-6
RTECS #:KI1410000
Other REC Limits:NONE RECOMMENDED

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INHALATION OF HIGH CONCENTRATIONS IS
    HARMFUL & MAY CAUSE HEART IRREGULARITIES, UNCONSCIOUSNESS, DEATH.
    INTENTIONAL MISUSE MAY CAUSE DEATH W/O WARNING. VAPORS REDUCE
    OXYGEN CONTENT OF THE AIR (ASPHYXIA TION). LIQUID CONTENT MAY CAUSE
    FROSTBITE.
Explanation of Carcinogenicity:NONE OF THE INGREGREDIENTS PRESENT AT
    0.1% OR GREATER ARE LISTED BY IARC, NTP, OSHA OR ACGIH AS
    CARCINOGENS.
Effects of Overexposure:LIQUID CONTACT:FROSTBITE. INHALATION:HIGH
    CONCENTRATIONS; COUGH, DIFFICULTY BREATHING, SHORTNESS OF BREATH,
    IRREGULAR PULSE, PALPITATIONS, INADEQUATE CIRCULATION, ABNORMAL
    KIDNEY FUNCTION.
Medical Cond Aggravated by Exposure:INDIVIDUALS W/PRE-EXISTING DISEASES
    OF CNS, CARDIOVASCULAR SYTEM, LUNGS OR KIDNEYS MAY HAVE INCREASED
    SUSCEPTIBILITY TO TOXICITY OF EXCESSIVE EXPOSURES.

=======================  First Aid Measures  =======================

First Aid:IF IRRITATION PERSISTS OR IS SEVERE, GET MEDICAL ATTENTION.
    EYE:FLUSH W/WATER FOR 15 MIN. SKIN:FLUSH AFFECTED AREA W/WATER.
    TREAT FOR FROSTBITE BY GENTLY WARMING AFFECTED AREA. INHALED:
    REMOVE FROM EX POSURE. KEEP VICTIM CALM. AID OR RESTORE BREATHING
    AS NEEDED. INGESTED:NOT CONSIDERED A POTENTIAL ROUTE OF EXPOSURE.

=====================  Fire Fighting Measures  =====================

Flash Point:WILL NOT BURN
Extinguishing Media:AS APPROPRIATE FOR COMBUSTIBLES IN AREA.
Fire Fighting Procedures:SELF-CONTAINED BREATHING APPARATUS IS REQUIRED
    IF CYLINDERS RUPTURE OR RELEASE UNDER FIRE CONDITIONS. USE WATER
    SPRAY/FOG TO COOL CONTAINERS.
Unusual Fire/Explosion Hazard:CYLINDERS ARE EQUIPPED W/TEMP/PRESSURE
    RELIEF DEVICES BUT MAY STILL RUPTURE UNDER FIRE CONDITIONS.
    DECOMPOSITION MAY OCCUR.

==================  Accidental Release Measures  ==================

Spill Release Procedures:VENTILATE AREA-ESPECIALLY LOW PLACE WHERE
    HEAVY VAPORS MIGHT COLLECT. WEAR SELF-CONTAINED BREATHING APPARATUS
    FOR LARGE SPILLS. REMOVE OPEN FLAMES.
Neutralizing Agent:MFR GAVE NO INFORMATION ON MSDS.

======================	Handling and Storage  ======================

Handling and Storage Precautions:AVOID BREATHING VAPORS. AVOID LIQUID
    CONTACT W/SKIN OR EYES.USE W/SUFFICIENT VENTILATION TO KEEP
    EMPLOYEE EXPOSURE BELOW RECOMMENDED LIMITS.
Other Precautions:STORE IN CLEAN,DRY AREA. DO NOT HEAT ABOVE 125F.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:UNDER NORMAL MFG CONDITIONS NO RESPIRATORY
    PROTECTION IS REQUIRED WHEN USING THIS PRODUCT.SELF-CONTAINED
    BREATHING APPARATUS (SCBA) IS REQUIRED IF SPILL OCCURS.
Ventilation:NORMAL VENTILATION FOR STDANDARD MFG PROCEDURES. IS
    GENERALLY ADEQUATE. USE LOCAL EXHAUST WHEN LARGE AMOUNTS RELEASED.
Protective Gloves:IMPERVIOUS GLOVES
Eye Protection:CHEMICAL SPLASH GOGGLES.
Other Protective Equipment:SELF-CONTAINED BREATHING APPARATUS IS
    REQUIRED IF A SPILL OCCURS
Work Hygienic Practices:MFR GAVE NO INFORMATION ON MSDS.
Supplemental Safety and Health
VENTILATION:MECHANICAL VENTILATION SHOULD BE USED IN LOW PLACES.

==================  Physical/Chemical Properties  ==================

HCC:G3
NRC/State Lic Num:NONE
Boiling Pt:B.P. Text:-27F,-33C
Vapor Pres:232 PSI
Vapor Density:3.7
Spec Gravity:1.16 G/CC
Evaporation Rate & Reference:<1  (CARBON TET = 1)
Appearance and Odor:LIQUIFIED GAS, COLORLESS, SLIGHT ETHEREAL ODOR,
    CLEAR APPEARANCE.
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
INCOMPATIBLE WITH ALKALI OR ALKALINE EARTH METALS - POWDERED AL, ZN,
    BE, ETC.
Stability Condition to Avoid:AVOID OPEN FLAMES AND HIGH TEMPERATURES.
Hazardous Decomposition Products:DECOMPOSED BY HIGHTEMPERATURES (OPEN
    FLAME, GLOWING METAL SURFACES,ETC) FORMING HCL OR HF ACIDS,
    CARBONYL HALIDES.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

====================  Disposal Considerations  ====================

Waste Disposal Methods:COMPLY WITH LOCAL, STATE & FEDERAL REGULATIONS.
    RECLAIM BY DISTILLATION OR REMOVE TO A PERMITTED WASTE DISPOSAL
    FACILITY.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.